In this article three dimension FEM is adopted in the stress analysis of bottom diversion outlet and notch segment of a RCC gravity dam when flowing design flood.
Research indicates that under full load operation of the reservoir, large local tensile stress will be produced at the dam heel and the outlet and inlet of the power penstock.