The results show that the full passage calculation can simulate the flow in the double channel impeller, especially at the inlet and exit, to assess the pump performance.
Double suction impeller is on both sides of the water, the impeller cover plate is symmetrical, the general flow of centrifugal pumpdouble suction impeller.