To raise permeate flux of ceramic membrane, reduce industrial specific power consumption, airlift circulation was led into membrane bioreactor under the suction filtration.
The experimental results show that the permeate was clear, and the content of metal ion was lower. The Membrane flux was larger and stable. Ceramic Membrane flux can be recovered by chemical clean.