The efficiency of a coal-fired thermal plant is typically in the range of 30%-35%. In a combined cycle gas turbine system running on natural gas, the maximum efficiency is in the range 45%-50%.
Taking a triple pressure reheat HRSG in the gas-steam combined cycle as an example, a general expression of the steam turbine thermalefficiency to coupling parameter with the unfired HRSG is derived.