This paper presents the vibration analysis and treatment of No. 2 bearing of the steam turbine for Unit 3 turbinedrivenfeed water pump a in Zhanjiang Power Plant.
Feedpump is one of the most important auxiliary equipments in power plants and the performance of turbinedriven boiler feedpump set adopted in large units is of particular importance.