The sensor can be fixed under the electromotor's end bracket. Leakageflux of motor stator and rotor does not affect the activity and measuring accuracy of the sensor.
该传感器可以安装在电动机内端盖处,电机定子与转子端部漏磁都不影响传感器的工作和测量精度。
2
The effect of flux-insulation methods of pole-to-pole leakage factor of PMSM with rotor of Us permanent magnet are computed and analyzed, and some conclusions are given.
计算分析U型永磁体转子磁路结构永磁同步电动机的隔磁措施对极间漏磁系数的影响,并得出了一些结论。
3
The Hall element which is adjacent to the end part of the rotor magnetic steel uses the magnetic fluxleakage as an operating signal of the Hall element.