The clean effects on polarplates and polar lines are increased. The problems of dust accumulation, agglomeration, brige connection and blockage are solved.
The result showed that the removal efficiency was improved with larger specific surface area of particle electrodes, decreased space between polarplates and higher voltage.
结果表明,填充颗粒比表面积越大、极板间距越小、电压越高,越有利于氟离子的去除。
3
The performance of the liquid feed direct methanol fuel cell was tested in a self designed experimental system. Two self-made gold plated stainless steel polarplates were installed in the fuel cell.