The impulse measurement errors of the XZF—900 precision resistor divider and the ZRF—1200 low damped capacitor divider are given from exponential wave tests and calculations.
Finally, the operation precision of the device is analyzed, the conclusion that the parasitical capacitor of the MOS transistor is the main factor to affect the precision is obtained.