Summary of Background Data. During C1 lateral mass screw insertion and in posterior C1-C2 fixation, iatrogenic injury of C1-C2 venous sinus results in bleeding, which is troublesome.
The technique of free hand insertion with the lateral mass screw of atlas and vertebra dentata pedicle screw is simple, fixation is reliability and is well worth to spreading.