This paper simply presents the commissioning of moistureseparator reheater (MSR) system and its monitored control system (RTC_5) of Qinshan NPP 300mw turbine generator.
It emphases discussing moisture structure applied in LP steam path and principle of moistureseparator reheater, the other methods of moisture removing are also introduced.
重点讨论了低压通流中采用的去湿结构和汽水分离再热系统的原理以及其它去湿方法的应用。
3
The moistureseparator reheater which used in nuclear power station was a complex structure, the NDT was according to British standards and French ALSTOM project standards.