Results There were no cases of orbital infection , implant extrusion, implant exposure or migration in 1-78 months of follow up.
结果随访1~ 78月,无眼座暴露、眶内感染或植入物排异、移位等并发症,外观满意。
2
Conclusion the ocular socket plasty with orbitalimplant of ha and secondary fitting peg is better than only the ocular socket plasty with orbitalimplant of ha.
AIM: To study the clinical effect of the hydroxyapatite orbitalimplant in surgery after enucleation and evisceration performed in 18 children with age of 3-12 years.