The test analysis shows that the fitted slope of test data to nominal stress and hot spot stress S-N curves for aluminum 5083 weldedjoint with longitudinal filletwelded gusset is 5.
The fatigue strength of the longitudinal filletweldedjoint specimen treated by ultrasonic peening increases by about 173% and the fatigue lifetime prolonges by 32~70 times.